I already have a predator 3500 generator and not looking to replace it. The 6 gal tank is about 5 inches above the generator. Thanks for sharing that information. It is a versatile and relatively quiet inverter generator that is both suitable for light loads and mid-size loads when connecting two units with a parallel kit. Let’s start with a few performance specifics, the Predator 3500 Inverter Generator has a 212 cc air-cooled gas engine that puts out a maximum of 3500 Watts, with a continuous running power of 3000 Watts.Basically, a 3000 Watt generator is plenty to run your RV’s AC unit and keep your fridge and lights on whilst allowing for a couple of low-drain appliances.The extra 500 watts surge power, allows for appliances that require extra po… Back last November we bought a Predator 3500 to use on our 35 foot travel trailer to use as temporary power while traveling in between camp sites to use at Truck stops, Walmart etc. In addition to capping or shutting off the tank vent on the Predator when using the extended run fuel tank kit, the instructions also make it plain that you must have the big tank higher than the the generator due to the fuel flow being strictly gravity/siphon. If a extended tank is used the pressure created in the generator tank will stop the gas from flowing from the aux tank. Try and avoid running out of fuel. Book Review: “My RV Mentor” Is Availab... 5 Ways Smartphones Can Improve Your RV Trips. One of the most common problems that a generator faces is that it starts well, run for a few seconds and then shuts down. Any suggestions? The battery is dead. Reviews are good...noise levels are similar...and it's only $670. I purchase the wheel kit with the hope that it would fit my 3500 Powerhorse generator by Northern Tool as the generators looked almost identical to the Harbor Freight 3500 Predator. As soon as the field is exited, the generator will produce power and the drill will turn on. Make sure you unplug the brush wires from the automatic voltage regulator or you will damage the regulator. 10 Winter Camping Items You Shouldn’t Travel... Camp Among Giant Redwoods In Northern California, http://www.pinellaspowerproducts.com/view/cfuelkit3400/. If spinning the chuck one direction does not work, try spinning the chuck in the other direction as you may have the reverse switch positioned backward. So I bought the extended run fuel tank kit advertised on ebay with hose, filter, squeeze ball, fittings and billet fuel cap (I already had my own brand new 6 1/2 gallon "outboard" tank.) It’s packed with features and a good amount of power making it suitable for almost any use. The rotor intersects this magnetic field as it is spun past the power winding, thus inducing a voltage in the rotor winding. This can get very problematic as it stops the important appliances from running, causes your security systems to go down and disrupts the business activities. Locate the voltage regulator for your generator.Unplug the two wires that connect to the generator brushes. The 2.6 gallon unleaded fuel tank is supposed to last 11 hours at 25% usage. If these fumes are not relieved pressure will build in the tank. Are you looking to run multiple electronics, then you will understand that … I checked and sure enough, somehow, the siphon had been broken. Problems I have noted, the gas tank on the generator has two lines from it, one to the carburetor the other to the carbon canister. Installed in a few minutes no problems. Do not contact the voltage regulator or other wires as dangerous voltages may be present that can cause electric shock. Planning a cross country trip and need to get this working. However, 4 hours later, the generator quit running. With 11 hours of run time at 25% load, this powerful inverter generator is ideal for powering RVs, camping, supplying household emergency power, and tailgating. This small amount of electricity is needed to create an even stronger electromagnet. Even with just a 2.5 gallon gas tank, it can get up to 11hr of runtime at 50% draw, due to the inverter technology. Well, interestingly, I have only had one chance to try out the extended run kit. Read honest and unbiased product reviews from our users. Thanks for sharing. The carburetor might be clogged or have bad fuel in the float bowl. The voltage going through the power winding creates a magnetic field which is intensified due to the iron core of the stator laminations. Worked as intended. Meet the Predator 3500 Watt Super Quiet Inverter Generator. Your generator does not have magnets. This will excite the field and the generator will now produce electricity. Plug in an electric drill into the generator receptacle.If the drill is reversible, move the direction switch to the forward position.Start the generator.While depressing the trigger on the drill, spin the drill chuck in reverse direction. The fuel valve is closed or clogged. Harbot Carburetor for Harbor Freight Chicago Predator 68527 68528 67560 67561 208CC 212CC R210III 3500 3050 3200 4000 Watts Gasoline Generator 4.8 out of 5 stars 34 $22.99 The generator should now be producing power again. After a few pumps of the primer bulb, I could see the fuel flowing through the glass filter as it filled the tank and gravity siphoning began. Predator 3500 … The wheel kit fit exactly to the Powerhorse 3500 without any modification. Find helpful customer reviews and review ratings for Predator 3500 Super Quiet Inverter Generator, Red at Amazon.com. This website is not affiliated with or endorsed by the Keystone RV Company or any of its affiliates in any way. But today I would like to respond and thank the forum for giving me inspiration and an Idea that I hope that will help a number of those with a running rich problem. From there it goes into the power winding of the stator. I used a clear hose with attwood quick release fittings on each end. Once current flow is present in the rotor winding the rotor has been flashed. Predator 8750 Generator. If anyone has made this work please contact me. However, the relatively short connecting hose meant that the generator was too close to our rear bedroom. When using a hose with a primer bulb on it I couldn't get the gas to flow from tank, even when pumping the bulb. Could I ask you what you capped the line off with? Please note this is the carburetor only and you will need to use the original step motor. A bad capacity will result in a low voltage reading from the generator as the power being generated will be from the residual magnetism of the rotor (usually about 2-5V). Hope that helps! I plumbed a 6 gallon portable tank to my Predator 3500 generator and could run at a 50% load for 15 hours vs. the previous 5 hour run time on the internal tank. Anyone who reads this please contact me if you have a answer. When I started the generator gas would not flow. It doesn't sound like the engine speeds up when this load (the 1200 watt heater) is plugged in. Still no siphon. It can also happen from running a generator with no load for too long. Then there's the issue of rain. What causes generators to stop producing power/voltage? When there is a small amount of magnetism left over from the last time the generator was running, it is called, There are a few methods of restoring a generator residual magnetism. Inverter generators are part of the new generation of gen… If a CARB generator's fuel system is sealed, and the breather tube hooks into the cannister...they why can't we just remove the hose from the Canister, and put it into a gas can? Anyone who reads this please contact me if you have a answer. Were you successful in getting this extended tank to work? I put a valve in the vent line on the internal generator tank which makes it easier to go between using an external tank or not using one. The canister is used to get rid of the vapors that are created when the gas in the generator tank gets hot and make fumes. Or what is the inner diameter size of that line? If you shut off a generator with the load connected, it can essentially drain or demagnetize the electromagnet. Thanks in advance, I’m following your footsteps with the cover as well. Hi S22. You could probably outfit the pvc structure with a tarp to shield the genny from the elements too. USA Canada UK EU AUS NZ Thanks. Sometimes, your generator may face some problems. The unit also has an illustrated quick start guide to make running the generator … Use caution not to get your hand or other materials caught in the chuck. Additionally, they are also pretty quiet or even comparable to well-known super quiet generators out there. I have been trying to get mine to work for some time. If these instructions do not help you to restore generator output power, the next step is to replace the Automatic Voltage Regulator as it may be damaged. Eric. The large capacity internal tank is what I've been looking for. I initially thought it would easiest to simply leave the tank on the back rack of our Outback 324CG. Now, how to tell the wife?? This residual magnetism can be lost naturally from not being used or from the load on your generator being connected when the generator is shut off. Sorry for the delay. Predator 3500 watt inverter carburetor This is a replacement carburetor with gaskets for the Predator 3500 watt Inverter generator. Though standard generators are commonly thought of, purchasing a generator with inverter technologyhas become much more attractive and beneficial. Niffy project. The generator gas tank has to be vent in some way. Specs Both the Predator 62523 and the Honda EU2000iT1A1 are rated for 1,600 watts, or a 2,000-watt surge load. Camper Report - Latest Equipment, Latest News, 10 Winter Destinations That Won’t Be Crowded, 5 Important Things To Consider While RV Shopping. AURORA no longer carries parts for portable diesel generators. When the residual magnetism is lost, the generator will produce no power at start-up. Before you shut it off, turn off the switch or breaker to disconnect the load. The magnets in the drill's motor induce a voltage into the motor winding, which is fed back through the trigger cord and into the generator receptacle. A simple 1200 watt heater will cause the overload light to come on and the voltage rapidly drop. Fits Model 63584 Had some issues and went thru some of the items on this thread,Anyone notice this on 3500 predator inverter generator.I noticed on Predator 3500 inverter generator air cleaner assy there are no slot cutouts for air intake to go thru foam filter. When the gas started to flow within 15 seconds the generator flooded out. If the gas tank is full, but no fuel is getting to the carburetor, … Predator 3500 and WEN 3800 are offering a decent amount of power in a fairly compact size and in our opinion, they are very convenient as well in operation. The plug is about 3/8" diameter and plugs the line just fine. I tightened all the connections, manually filled the tank to the top, and tried again. The magnetic field is created by taking some of the generator output voltage and converting it to DC and feeding it to a coil to make an electromagnet. Nice little exoskeleton and fuel table. The company I bought the kit from is MRI-Denver and they included fairly detailed instructions with the kit. Generators need to work and it helps maintain that residual magnetism. If you need parts, please try www.GeneratorGuru.com or Amazon and eBay. I made a pvc pipe so I could blow into the vent on top of the filler cap on 6 gal tank.